The BPQJ series Mining Explosion-proof and Intrinsically-safe Combined Frequency Conversion Starter is mining explosion-proof and intrinsically-safe Exd [ib] I. It is composed of a variable-frequency speed control system, an electrical control system, a display system and a parameter setting unit. It applies advanced IGBT frequency control and vector current loop control theory to the speed regulation device with high degree of automation and leading technology. Tests and inspections such as flameproof, cyclic damp heat test and electric property have been conducted for the device, and relevant certificates have been obtained. The VFD has perfect protection functions such as short-circuit protection, overcurrent, overload, overvoltage, under-voltage and over-temperature protections. The VFD core is the IGBT semiconductor switching device, adopting the mature high-quality device of German INFINEON; the drive circuit adopts an integrated circuit with high precision designed with imported chip. Through controlling the software design, it can rapidly handle various external input orders and cope with emergency circumstances. Under the non-stop circumstance, the system can automatically remove some errors so as to reduce frequent participation of users.
Product Model | BPQJ-(400, 250)/1140 | BPQJ-(500, 300)/1140 |
Explosion Prevention Type | Exd[ib]ΙMb | |
Rated Power | 400kW | 500kW |
Rated Operating Voltage | Three-phase 1140VAC,50Hz±0.5% | |
Voltage Fluctuation Range | -20%~+20% | |
Rated Current | 250A | 300A |
Output Voltage | 0~1140VAC | |
Output Current | 0~250A | 0~300A |
Output Frequency | 0~50Hz | |
Carrier Frequency | 1.5kHz | |
Working System | Long term working system | |
Cooling Mode | Natural cooling | |
Control Motor | Synchronous (Asynchronous) Motor | Synchronous (Asynchronous) Motor |
1. Synchronous VFD's starting torque is large, which can reach 200% of the rated torque;
2. Belt VFD starts on ramp, which can reduce the damage to the belt and drum when starting;
3. Synchronous direct-driven VFD is efficient and energy-saving, and the power saving efficiency can reach more than 20%;
4. Synchronous direct-driven system eliminates the decelerator, hydraulic coupler and other equipment, so that the overall efficiency of the system can be increased to more than 95%;
5. Abundant communication functions. It can support CAN, RS485, PROFBUS, DP and other communication interface accesses, can communicate with the upper computer, the centralized control of the operation of multiple equipment, and can monitor the operation data transmitted to the ground dispatching station online;
6. Historical data storage. It can save the operation data of recent one year, and the data can be exported in EXCEL format, transformed into graphic mode through the software developed by Huaxin, which is convenient for understanding the historical working condition of belt conveyor.
Specification & Model | Overall Dimensions mm | Weight Kg |
BPQJ-(400, 250)/1140 | 1723 x1437 x1250 | 2000 |
BPQJ-(500, 300)/1140 | 1723 x1437 x 1285 | 2300 |
1. Asynchronous VFD's starting torque is large, which can reach 150% of the rated torque;
2. Synchronous VFD's starting torque is large, which can reach 200% of the rated torque;
3. Belt frequency converter starts on ramp, which can minimize damage to the belt and drum when starting;
4. Synchronous direct-driven VFD is efficient and energy-saving, and the power saving effect can reach more than 20%;
5. Synchronous direct-driven system eliminates the decelerator, hydraulic coupler and other equipment, so that the overall efficiency of the system can be increased to more than 95%.
The BPQJ Series Mining Explosion-proof and Intrinsically-safe Combined Frequency Conversion Starter can be used for regulating the speed of mining belt conveyor motors, applicable to frequency conversion driving system of synchronous or asynchronous motors. This product belongs to two-quadrant working system and it can meet the starting and speed governing requirements of asynchronous motors for mining belt conveyors and scraper.
1. Ambient temperature: 0℃ - +40℃ (32°F to 104°F);
2. Maximum average relative humidity: ≤ 95% (+25℃/77°F);
3. Atmospheric pressure: 80kPa-106kPa (+25℃/77°F);
4. No occasion with serious dripping and splashing in the surrounding;
5. Environment with explosive gases, such as methane and coal dust, but without corrosive gases.
©1996-2023 晉ICP備07500050號 Huaxin Copyright
©1996-2023 晉ICP備07500050號 Huaxin Copyright